ACS Phone: +43 7228 20088 0

MAL-C PUR SKL

Anwendung

As optimized supply cable for the supply to motors, in particular to DNC motors, servo-motors. These cables are specially designed for use in power drag chains, handling equipment, robotics, tooling machinery, processing and manufacturing machinery. Optimised insulation materials ensure resistance to oils (including mineral oils), greases, coolants, hydraulic fluids as well as many alkalis and solvents. Favourable outer diameters, reduced weights and enhanced torsion characteristics assure the use in multi-layer operations with extremely high continuous bending loads. Suitable for outdoor use.


art. no.
dimensions
colour
outer-Ø
weight
07704001 4 x 1,5 grey 11,5 220
07704002 4 x 2,5 grey 13,1 340
07704003 4 x 4 grey 15,5 490
07704004 4 x 6 grey 16,8 680
07704005 4 x 10 grey 20,8 1035
07704006 4 x 16 grey 24 1460
07704007 4 x 25 grey 29 1990
07704008 4 x 35 grey 34 2535
07704009 4 x 50 grey 42,8 3360
07704010 4 x 70 grey 52,5 4650
07704011 4 x 95 grey 58 6090
07704012 4 x 120 grey 60,5 7380
inner conductor extra fine wire conductors, bare copper acc. DIN VDE 0295 cl. 6 / IEC 60228 cl. 6 / BS 6360 cl. 6
core insulation TPE thermoplastic elastomers
core colour code black cores with continuous white numbering acc. to DIN VDE 0293, green-yellow earth core in the outer layer
stranding element cores are stranded in layer with short lay-length and stabilising filler
coat fleece wrapping facilitates sliding, TPE inner jacket
overall shield braid shield copper tinned
outer sheath material PUR

acc. to DIN VDE 0293, 0295, 0250, 0281
CE = The product is conformed with the EC Low-Voltage Directive 2014/35/EU.

inner conductor extra fine wire conductors, bare copper acc. DIN VDE 0295 cl. 6 / IEC 60228 cl. 6 / BS 6360 cl. 6
core insulation TPE thermoplastic elastomers
core colour code black cores with continuous white numbering acc. to DIN VDE 0293, green-yellow earth core in the outer layer
stranding element cores are stranded in layer with short lay-length and stabilising filler
coat fleece wrapping facilitates sliding, TPE inner jacket
overall shield braid shield copper tinned
outer sheath material PUR
rated voltage Uo/U: 600/1000 V
test voltage 4000 V
insulation resistance min. 20 MOhm x km
bending radius moved 10
bending radius fixed 5
operation temp. fixed -50°C … +90°C
operation temp. moved -30°C … +80°C
fire behavior flame retardant
fire test acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1