E-AYY-O/J

Application

Power cables for energy supply are installed in open air, in underground, in water, indoors, in cable ducts, power stations, for industry and distribution boards as well as in subscriber networks, accordance with the building regulations.


art. no.
type
dimensions
outer-Ø
weight
power load earth
power load air
01305044 -O 1 x 50 rm 14,5 296 151 A 131 A
01305043 -O 1 x 70 rm 16,1 375 185 A 166 A
01305041 -O 1 x 95 rm 18,1 485 222 A 205 A
01305045 -O 1 x 120 rm 19,6 580 253 A 239 A
01305054 -J 1 x 120 rm 19,6 580 253 A 239 A
01305027 -O 1 x 150 rm 21,4 780 284 A 273 A
01305028 -O 1 x 185 rm 23 895 322 A 317 A
01305001 -O 1 x 240 rm 26 1058 375 A 378 A
01305029 -O 1 x 300 rm 31,2 1344 425 A 437 A
01305047 -O 1 x 400 rm 32,3 1890 487 A 513 A
01305048 -O 1 x 500 rm 36,2 2600 558 A 600 A
01305049 -O 1 x 630 rm 39,8 2780 635 A 701 A
01305002 -O 3 x 240/120 53 3751 364 A 338 A
01305018 -J 3 x 240/120 53 3751 364 A 338 A
01305004 -O 4 x 25 rm 25,4 843 102 A 82 A
01305051 -J 4 x 25 rm 25,4 843 102 A 82 A
01305005 -O 4 x 35 sm 26,7 956 123 A 100 A
01305039 -J 4 x 35 sm 26,7 956 123 A 100 A
01305007 -O 4 x 50 sm 29,9 1021 144 A 119 A
01305020 -J 4 x 50 sm 29,9 1021 144 A 119 A
01305008 -O 4 x 70 sm 34,4 1341 179 A 152 A
01305037 -J 4 x 70 sm 34,4 1341 179 A 152 A
01305010 -O 4 x 95 sm 37 1805 215 A 186 A
01305021 -J 4 x 95 sm 37 1805 215 A 186 A
01305012 -O 4 x 120 sm 41,8 2225 245 A 216 A
01305022 -J 4 x 120 sm 41,8 2225 245 A 216 A
01305014 -O 4 x 150 sm 46 2605 275 A 246 A
01305024 -J 4 x 150 sm 46 2605 275 A 246 A
01305016 -O 4 x 185 sm 51 3242 313 A 285 A
01305025 -J 4 x 185 sm 51 3242 313 A 285 A
01305017 -O 4 x 240 sm 57 4217 364 A 338 A
01305026 -J 4 x 240 sm 57 4217 364 A 338 A
01305063 -J 5 x 16 rm 21 808 -0 -0
01305055 -J 5 x 25 rm 27,5 1018 -0 -0
01305056 -J 5 x 35 rm 30,8 1218 -0 -0
01305057 -J 5 x 50 rm 31 1860 -0 -0
01305058 -J 5 x 70 rm 34 2350 -0 -0
01305059 -J 5 x 95 rm 38 3050 -0 -0
01305060 -J 5 x 120 rm 44 3250 -0 -0
01305061 -J 5 x 150 rm 45,8 4050 -0 -0
01305062 -J 5 x 185 rm 50 4900 -0 -0
inner conductor solid or stranded, alu conductor to DIN VDE 0295 cl. 1 or cl. 2, BS 6360 cl. 1 or cl. 2 and IEC 60228 cl. 1 or cl. 2
core insulation polyvinylchlorid compound (PVC)
core colour code HD 308 S2, 7 cores black with continuous white numbers printed
stranding element multi cores stranded in layers
coat filler sheath or tape
outer sheath material PVC - polyvinylchlorid compound, black

ÖVE K 23 and K 603
CE = The product is conformed with the EC Low-Voltage Directive 2014/35/EU.

inner conductor solid or stranded, alu conductor to DIN VDE 0295 cl. 1 or cl. 2, BS 6360 cl. 1 or cl. 2 and IEC 60228 cl. 1 or cl. 2
core insulation polyvinylchlorid compound (PVC)
core colour code HD 308 S2, 7 cores black with continuous white numbers printed
stranding element multi cores stranded in layers
coat filler sheath or tape
outer sheath material PVC - polyvinylchlorid compound, black
rated voltage Uo/U: 0,6/1 kV
test voltage 4000 V
bending radius fixed single core: 15
multi core: 12
operation temp. fixed -20°C … +70°C
operation temp. moved -5°C … +70°C
conductor temp max. +70°C
short circuit temperature up to 300 mm²: max. +160°C
from 400 mm²: max. +140°C
short circuit duration 5 sec.
fire behavior flame retardant
fire test acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1