ACS Phone: +43 7228 20088 0

AE-L-Si/S/Si, AN-K-Si/S/Si, AP-S-Si/S/Si

Application

For use in dry, damp and wet areas. Compensating cables are an essential part of exact and precise measuring leads from the thermocoupling elements to the measure gauge. The fitted connection line between the thermocouple and the comparative part must have the same thermoelectrical characteristics as the thermocouple. The difference of temperature is measured between the measuring point and the comparative part of the cable.


art. no.
type
dimensions
colour
outer-Ø
weight
03601020 AE-L-SiSSi/Fe-CuNi 2 x 1,5 blue 7,8 105
03602010 AN-K-SiSSi/SoNiCr-SoNi 2 x 1,5 green 7,8 105
03603031 AP-S-SiSSi/SoPtRh-SoPt 2 x 1,5 orange 7,8 105
inner conductor Conductors of stranded wires or solid, insulated with special material, Conductors: Fe/CuNi, Ni/Cr Ni or Pt Rh/Pt
core insulation silicone
core colour code Colour code for pairs from 2 pairs and above the individual pairs number coded
stranding element cores twisted
overall shield screened braiding of galvanized steel
outer sheath material silicone

IEC 60584 (core identification), DIN IEC 584, DIN 43710

inner conductor Conductors of stranded wires or solid, insulated with special material, Conductors: Fe/CuNi, Ni/Cr Ni or Pt Rh/Pt
core insulation silicone
core colour code Colour code for pairs from 2 pairs and above the individual pairs number coded
stranding element cores twisted
overall shield screened braiding of galvanized steel
outer sheath material silicone
test voltage 500 V
insulation resistance min. 10 MOhm x km
inductance < 1 mH/km
fire test to DIN VDE 0482 part 266-2/HD 405.3, BS 4066 part 3/EN 50266-2/IEC 60332-3 (to DIN VDE 0472 part 804 Type of test C)