ACS Phone: +43 7228-2008-0

… always

a cable length ahead!

N2XH

Application

Halogen-free power cables with enhanced characteristics in case of fire are used for applications where harm to human life and damage to property must be prevented in the event of fire, e.g. in industrial installations, communal establishments, hotels, airports, underground stations, railway stations, hospitals department stores, banks, schools theaters, multi-storey buildings, process control centres etc. Suitable for fixed installation in dry, damp or wet environments, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications and in underground by using in conduits or tubes.


art. no.
dimensions
colour
outer-Ø
weight
02202024 1 G 16 re black 12 270
02202026 1 G 25 rm black 14 380
02202028 1 G 35 rm black 15 490
02202029 1 G 50 rm black 16 620
02202031 1 G 70 rm black 18 700
02202032 1 G 95 rm black 20 1200
02202099 1 x 6,0 re black 9 160
02202023 1 x 16 re black 12 270
02202025 1 x 25 rm black 14 380
02202027 1 x 35 rm black 15 490
02202004 1 x 50 rm black 16 620
02202030 1 x 70 rm black 18 700
02202005 1 x 95 rm black 20 1200
02202001 1 x 120 rm black 22 1500
02202033 1 x 150 rm black 24 1700
02202034 1 x 185 rm black 26 2200
02202002 1 x 240 rm black 29 2750
02202036 1 x 300 rm black 31 3300
02202037 2 x 1,5 re black 12 180
02202038 2 x 2,5 re black 12 210
02202039 2 x 4,0 re black 13 270
02202040 2 x 6,0 re black 14 340
02202041 2 x 10 re black 16 450
02202016 3 G 1,5 re black 12 200
02202043 3 G 2,5 re black 13 250
02202044 3 G 4,0 re black 14 330
02202045 3 G 6,0 re black 15 410
02202046 3 G 10 re black 16 550
02202047 3 G 16 re black 20 790
02202048 3 G 25 rm black 24 1200
02202087 3 G 25/16 rm black 23 1200
02202049 3 G 35 sm black 27 1050
02202085 3 G 35/16 rm black 25 1640
02202050 3 G 50 sm black 29 1800
02202056 3 G 50/25 rm black 26 2200
02202057 3 G 70/35 sm black 28 2950
02202058 3 G 95/50 sm black 41 3900
02202014 3 G 120/70 sm black 45 4800
02202059 3 G 150/70 sm black 49 5750
02202060 3 G 185/95 sm black 55 7200
02202009 3 G 240/120 sm black 58 9150
02202077 4 G 1,5 re black 13 230
02202078 4 G 2,5 re black 14 290
02202018 4 G 4,0 re black 15 380
02202003 4 G 6 re black 16 490
02202007 4 G 10 re black 18 670
02202102 4 G 10 rm black 18 670
02202063 4 G 16 re black 20 930
02202101 4 G 16 rm black 20 930
02202008 4 G 25 rm black 26 1450
02202011 4 G 35 sm black 29 1900
02202012 4 G 50 sm black 32 2300
02202013 4 G 70 sm black 37 3200
02202064 4 G 95 sm black 41 4200
02202065 4 G 120 sm black 42 5500
02202066 4 G 150 sm black 45,8 6550
02202019 5 G 1,5 re black 14 270
02202067 5 G 2,5 re black 15 340
02202010 5 G 4,0 re black 16 450
02202015 5 G 6,0 re black 17 560
02202022 5 G 10 re black 20 840
02202103 5 G 10 rm black 20 840
02202020 5 G 16 re black 22 1200
02202104 5 G 16 rm black 22 1200
02202021 5 G 25 rm black 32 2000
02202088 5 G 35 rm black 33 2400
02202089 5 G 50 rm black 37 3500
02202090 5 G 70 rm black 44 4610
02202068 7 G 1,5 re black 14 310
02202073 7 G 2,5 re black 15 400
02202071 7 G 4,0 re black 16 560
02202069 10 G 1,5 re black 17 420
02202006 12 G 1,5 re black 18 460
02202074 12 G 2,5 re black 19 600
02202070 14 G 1,5 re black 20 540
02202076 14 G 2,5 re black 20 670
02202072 19 G 1,5 re black 21 650
02202096 19 G 2,5 re black 24 800
02202061 24 G 1,5 re black 22 760
02202075 24 G 2,5 re black 25 1050
02202100 30 G 1,5 re black 22,6 730
inner conductor bare copper conductor to DIN VDE 0295 cl. 1 or cl. 2, HD 383
core insulation cross-linked polyethylene compound 2XI1, to HD 604 S1
core colour code acc. to HD 308 S2
stranding element cores stranded in layers
coat covered by filling compound or wrapped tape
outer sheath material halogen-free polymer HM4

acc. to DIN VDE 0276 part 604, HD 604 S1 part 1 and part 5G.
CE = The product is conformed with the EC Low-Voltage Directive 2014/35/EU.

inner conductor bare copper conductor to DIN VDE 0295 cl. 1 or cl. 2, HD 383
core insulation cross-linked polyethylene compound 2XI1, to HD 604 S1
core colour code acc. to HD 308 S2
stranding element cores stranded in layers
coat covered by filling compound or wrapped tape
outer sheath material halogen-free polymer HM4
rated voltage Uo/U: 0,6/1 kV
test voltage 4 kV
operation temp. fixed -30°C … +90°C
operation temp. moved -5°C … +50°C
conductor temp max. +90°C
halogenfree acc. to VDE 0482 part 267,
DIN EN 50267-2-1, IEC 60754-1
radiation resistance up to 100x106 cJ/kg (up to 100 Mrad)
corrosivity of combustion gases to IEC 60754-2 or VDE 0482 Teil 267-2-3
fire behavior flame retardant, no separation of corrosive or toxic gases, limited propagation of fire, low smoke development.
fire test acc. to VDE 0482 part 266-2, BS 4066
part 3, DIN EN 50266-2, IEC 60332-3

Contact

Export

Management

Angela Mesarosch

Management Eastern Europe

phone +43 7228 20088-133
Fax +43 7228 20088-200
Mobil +43 664 9624355
mesarosch.angela@acs.at

Prok. Manfred Lederhilger

Export Management

phone +43 7228 20088-342
Fax +43 7228 20088-349
Mobil +43 664 1724858
lederhilger.manfred@acs.at

Division Management

Veronika Jautz

Czech Republic and Slovakia

phone +43 7228 20088 132
Fax +43 7228 20088 200
jautz.veronika@acs.at

Jaroslav Loučka

Czech Republic and Slovakia

Mobil +42 0727 835 409
loucka.jaroslav@acs.at

Angela Mesarosch

Hungary, Romania, Slovenia, Croatia, Serbia, Macedonia

phone +43 7228 20088-133
Fax +43 7228 20088-200
Mobil +43 664 9624355
mesarosch.angela@acs.at

Export Sales Assistant

Bc. Mariana Horak

phone +43 7228 20088-131
Fax +43 7228 20088-200
horak.mariana@acs.at

Philipp Szatmari

phone +43 7228 20088 134
Fax +43 7228 20088 200
szatmari.philipp@acs.at