RE-2Y(St)Yv PiMF (DimF)

Application

Instrumentation cables are used in data processing and process control. The individual screening of the pairs guarantee high cross-talk attenuation. The electrostatic screen protect the screened pairs against outer electrostatic interference fields. Low level of line attenuations and low mutual capacitances enable long transmission distances and fast pulse acceleration. Instrumentation cables are suitable for fixed installations in damp locations, in open spaces and for underground laying.


art. no.
dimensions
colour
outer-Ø
weight
03219013 1x2 x 1 black 10 90
03219021 1x2 x 1 blue 10 90
03219003 2x2 x 0,5 black 12 128
03219064 2x2 x 0,5 blue 12 128
03219058 2x2 x 0,75 black 11,4 142
03219059 2x2 x 0,75 blue 11,4 142
03219082 2x3 x 0,75 black 12,2 167
03219083 2x3 x 0,75 blue 12,2 167
03219094 2x2 x 0,75 black 11,4 142
03219095 2x2 x 0,75 blue 11,4 142
03219014 2x2 x 1 black 11 135
03219022 2x2 x 1 blue 11 135
03219001 2x2 x 1,3 black 11,7 184
03219029 2x2 x 1,3 blue 11,7 184
03219044 2x2 x 1,3 black 11,7 184
03219045 2x2 x 1,3 blue 11,7 184
03219004 4x2 x 0,5 black 127 170
03219041 4x2 x 0,5 blue 127 170
03219067 4x2 x 0,75 black 12,8 196
03219068 4x2 x 0,75 blue 12,8 196
03219069 4x2 x 0,75 black 12,8 196
03219070 4x2 x 0,75 blue 12,8 196
03219086 4x3 x 0,75 black 13,8 242
03219087 4x3 x 0,75 blue 13,8 242
03219015 4x2 x 1 black 13,5 225
03219023 4x2 x 1 blue 13,5 225
03219005 4x2 x 1,3 black 15,2 269
03219030 4x2 x 1,3 blue 15,2 269
03219100 6x2 x 0,5 blue 14 215
03219101 6x2 x 0,5 black 14 215
03219016 6x2 x 1 black 15,3 263
03219024 6x2 x 1 blue 15,3 263
03219031 6x2 x 1,3 blue 16,7 370
03219032 6x2 x 1,3 black 16,7 370
03219050 6x2 x 1,3 black 16,7 370
03219051 6x2 x 1,3 blue 16,7 370
03219096 8x2 x 0,5 black 13,8 215
03219099 8x2 x 0,5 blue 13,8 215
03219071 8x2 x 0,75 black 15,9 318
03219072 8x2 x 0,75 blue 15,9 318
03219073 8x2 x 0,75 black 15,9 318
03219074 8x2 x 0,75 blue 15,9 318
03219090 8x3 x 0,75 black 17,9 413
03219091 8x3 x 0,75 blue 17,9 413
03219017 8x2 x 1 black 17,3 308
03219025 8x2 x 1 blue 17,3 308
03219033 8x2 x 1,3 black 18,8 442
03219034 8x2 x 1,3 blue 18,8 442
03219052 8x2 x 1,3 black 18,8 442
03219053 8x2 x 1,3 blue 18,8 442
03219106 10x2 x 1 black 19,2 345
03219107 10x2 x 1 blue 19,2 345
03219097 12x2 x 0,5 black 17,6 351
03219102 12x2 x 0,5 blue 17,6 351
03219060 12x2 x 0,75 black 17,9 400
03219075 12x2 x 0,75 black 17,9 400
03219076 12x2 x 0,75 blue 17,9 400
03219077 12x2 x 0,75 blue 17,9 400
03219018 12x2 x 1 black 21,2 425
03219026 12x2 x 1 blue 21,2 425
03219065 12x3 x 1 black 23,2 753
03219066 12x3 x 1 blue 23,2 753
03219035 12x2 x 1,3 black 21,4 593
03219036 12x2 x 1,3 blue 21,4 593
03219054 12x2 x 1,3 black 21,4 593
03219055 12x2 x 1,3 blue 21,4 593
03219103 12x2 x 1,3+1x1,5gg black 21,4 593
03219010 16x2 x 0,5 black 19,8 430
03219078 16x2 x 0,75 black 20,8 538
03219079 16x2 x 0,75 blue 20,8 538
03219080 16x2 x 0,75 black 20,8 538
03219081 16x2 x 0,75 blue 20,8 538
03219092 16x3 x 0,75 black 23,3 710
03219093 16x3 x 0,75 blue 23,3 710
03219019 16x2 x 1 black 23,5 540
03219027 16x2 x 1 blue 23,5 540
03219104 16x2 x 1 black 23,5 540
03219105 16x2 x 1 blue 23,5 540
03219037 16x2 x 1,3 black 24,7 789
03219038 16x2 x 1,3 blue 24,7 789
03219042 16x2 x 1,3 blue 24,7 789
03219043 16x2 x 1,3 black 24,7 789
03219056 20x3 x 1 black 28 1032
03219057 20x3 x 1 blue 28 1032
03219039 20x2 x 1,3 blue 27,3 948
03219040 20x2 x 1,3 black 27,3 948
03219011 20x2 x 1,5 black 29,1 1100
03219012 24x2 x 0,5 black 23,6 604
03219061 24x2 x 0,75 black 24 710
03219062 24x2 x 0,75 blue 24 710
03219020 24x2 x 1 black 29 757
03219028 24x2 x 1 blue 29 757
03219048 24x3 x 1 black 30 1250
03219049 24x3 x 1 blue 30 1250
03219006 24x2 x 1,3 black 29,4 1104
03219007 24x2 x 1,3 blue 29,4 1104
03219008 24x2 x 1,3 black 29,4 1104
03219009 24x2 x 1,3 blue 29,4 1104
03219063 24x2 x 1,3 blue 29,4 1104
03219046 32x2 x 1 black 33,2 1100
03219047 32x2 x 1 blue 33,2 1100
03219098 36x2 x 0,5 black 26,8 805
inner conductor bare copper stranded wires 0,5 mm² (7x0,3 mm) 0,75 mm² (7x0,37 mm) 1,3 mm² (7x0,49 mm)
core insulation polyethylene compound (PE)
core colour code with numbering pair: a-core black, b-core white triple: a-core black, b-core white, c-core red with number print 1/1, 2/2, etc.
stranding element cores stranded in pairs with optimal lay-length
shielding 1 PiMF, PiMF (pair in metal foil): foil taping, drain-wire, Cu-bare 0,6 mm ø, plastic coated alu-foil and plastic foil PiMFe stranded in layer, 1 communication core 0,5 mm², PE-insulated orange (communication core for multicore version)
overall shield electrostatic screen (St) of plastics-coated metal foil and tinned drain-wire 0,5 mm² (7x0,3 mm)
outer sheath material PVC, reinforced, black or blue


CE = The product is conformed with the EC Low-Voltage Directive 2014/35/EU.

inner conductor bare copper stranded wires 0,5 mm² (7x0,3 mm) 0,75 mm² (7x0,37 mm) 1,3 mm² (7x0,49 mm)
core insulation polyethylene compound (PE)
core colour code with numbering pair: a-core black, b-core white triple: a-core black, b-core white, c-core red with number print 1/1, 2/2, etc.
stranding element cores stranded in pairs with optimal lay-length
shielding 1 PiMF, PiMF (pair in metal foil): foil taping, drain-wire, Cu-bare 0,6 mm ø, plastic coated alu-foil and plastic foil PiMFe stranded in layer, 1 communication core 0,5 mm², PE-insulated orange (communication core for multicore version)
overall shield electrostatic screen (St) of plastics-coated metal foil and tinned drain-wire 0,5 mm² (7x0,3 mm)
outer sheath material PVC, reinforced, black or blue
test voltage core/core: 2000 V
core/screen: 1000 V
insulation resistance min. 5 GOhm x km
operating peak voltage max. 300 V (not for purposes of high current and power installation)
inductance max. 0,75 mH/km
operating capacity at 800 Hz core/core 0,5 mm²: 60nF/km for 1 and 2 pairs: 75 nF/km core/core 1,3 mm²: 75 nF/km for 1 and 2 pairs: 100 nF/km
bending radius moved 7,5
operation temp. fixed -40°C … +70°C
operation temp. moved -5°C … +50°C
fire behavior self-extinguishing and flame retardant
fire test acc. to VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1

Contact

Export

Management

Angela Mesarosch

Management Eastern Europe

phone +43 7228 20088-133
Fax +43 7228 20088-200
Mobil +43 664 9624355
mesarosch.angela@acs.at

Prok. Manfred Lederhilger

Export Management

phone +43 7228 20088-342
Fax +43 7228 20088-349
Mobil +43 664 1724858
lederhilger.manfred@acs.at

Division Management

Veronika Jautz

Czech Republic and Slovakia

phone +43 7228 20088 132
Fax +43 7228 20088 200
jautz.veronika@acs.at

Jaroslav Loučka

Czech Republic and Slovakia

Mobil +42 0727 835 409
loucka.jaroslav@acs.at

Angela Mesarosch

Hungary, Romania, Slovenia, Croatia, Serbia, Macedonia

phone +43 7228 20088-133
Fax +43 7228 20088-200
Mobil +43 664 9624355
mesarosch.angela@acs.at

Export Sales Assistant

Bc. Mariana Horak

phone +43 7228 20088-131
Fax +43 7228 20088-200
horak.mariana@acs.at

Philipp Szatmari

phone +43 7228 20088 134
Fax +43 7228 20088 200
szatmari.philipp@acs.at