YSLYQY

Application

This cables are used as measuring and control cables in tool machinery, plant installation, power stations and in data equipment. The braided screen offers best possible protection against mechanical damage. The galvanized coating on the steel wire braiding not only helps protect against corrosion, but also notably improves the soldering performance. The clear transparent outer sheath gives the cable in addition an optical revaluation.


art. no.
type
dimensions
colour
outer-Ø
weight
00903112 -JB 4 G 4,0 transparent 16,1 318
00903069 -JB 4 G 6,0 transparent 18,8 440
00903094 -JB 4 G 25 transparent 32,2 1350
00903095 -JB 4 G 35 transparent 36 1839
00903100 -JB 4 G 50 transparent 43 2605
00903101 -JB 4 G 70 transparent 47 3453
00903134 -JB 5 G 4,0 transparent 17,8 392
inner conductor fine-stranded bare copper acc. DIN VDE 0295 cl. 5 / IEC 60228 cl. 5
core insulation polyvinylchlorid compound (PVC)
core colour code acc. to JB/OB colour code, green-yellow earth core in the outer layer (3 cores and above)
stranding element core colour coded as per JB/OB colour code, Green-yellow earth core in the outer layer (3 cores and above)
coat polyvinylchlorid compound (PVC)
overall shield galvanized steel wire screening
outer sheath material special polyvinylchlorid (PVC)

adapted to DIN VDE 0245, 0281, 0293, 0295
CE = The product is conformed with the EC Low-Voltage Directive 2014/35/EU.

inner conductor fine-stranded bare copper acc. DIN VDE 0295 cl. 5 / IEC 60228 cl. 5
core insulation polyvinylchlorid compound (PVC)
core colour code acc. to JB/OB colour code, green-yellow earth core in the outer layer (3 cores and above)
stranding element core colour coded as per JB/OB colour code, Green-yellow earth core in the outer layer (3 cores and above)
coat polyvinylchlorid compound (PVC)
overall shield galvanized steel wire screening
outer sheath material special polyvinylchlorid (PVC)
rated voltage Uo/U: 300/500 V
test voltage 4000 V
breakdown voltage min. 8000 V
insulation resistance min. 20 MOhm x km
bending radius moved 20
bending radius fixed 6
operation temp. fixed -40°C … +70°C
operation temp. moved -5°C … +70°C
radiation resistance up to 80x106 cJ/kg (up to 80 Mrad)
fire behavior self-extinguishing and flame retardant acc. to VDE 0482 part 332-1-2,
EN 60332-1-2, IEC 60332-1

Contact

Export

Management

Angela Mesarosch

Management Eastern Europe

phone +43 7228 20088-133
Fax +43 7228 20088-200
Mobil +43 664 9624355
mesarosch.angela@acs.at

Prok. Manfred Lederhilger

Export Management

phone +43 7228 20088-342
Fax +43 7228 20088-349
Mobil +43 664 1724858
lederhilger.manfred@acs.at

Division Management

Veronika Jautz

Czech Republic and Slovakia

phone +43 7228 20088 132
Fax +43 7228 20088 200
jautz.veronika@acs.at

Jaroslav Loučka

Czech Republic and Slovakia

Mobil +42 0727 835 409
loucka.jaroslav@acs.at

Angela Mesarosch

Hungary, Romania, Slovenia, Croatia, Serbia, Macedonia

phone +43 7228 20088-133
Fax +43 7228 20088-200
Mobil +43 664 9624355
mesarosch.angela@acs.at

Export Sales Assistant

Bc. Mariana Horak

phone +43 7228 20088-131
Fax +43 7228 20088-200
horak.mariana@acs.at

Philipp Szatmari

phone +43 7228 20088 134
Fax +43 7228 20088 200
szatmari.philipp@acs.at