Roboflex 2001-C

Application

These special robotic control and signal cables specially designed for torsion and bending stresses in robots and connecting handling tools. EMC = Electromagnetic compatibillity. To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.


art. no.
dimensions
colour
outer-Ø
weight
01165006 10 x 0,14 black 7,8 62
01165007 12 x 0,14 black 7,8 95
01165010 12 x 0,25 black 8,3 126
01165012 12 x 0,34 black 8,8 160
01165002 12 x 0,50 black 11,2 175
01165015 12 x 0,75 black 11,8 220
01165017 12 x 1,0 black 13 265
01165020 12 x 1,5 black 16,2 345
01165008 18 x 0,14 black 9,7 120
01165005 18 x 0,25 black 10,1 164
01165004 18 x 0,34 black 10,8 210
01165001 18 x 0,50 black 13,6 231
01165016 18 x 0,75 black 15 305
01165018 18 x 1,0 black 16,1 390
01165021 18 x 1,5 black 20,3 485
01165009 25 x 0,14 black 10,9 158
01165011 25 x 0,25 black 11,1 215
01165013 25 x 0,34 black 12,1 305
01165014 25 x 0,50 black 14,8 347
01165003 25 x 0,75 black 16,6 415
01165019 25 x 1,0 black 18 540
01165022 25 x 1,5 black 22,5 710
inner conductor fine wire or extra fine wire conductors, bare copper acc. DIN VDE 0295 cl.5 or 6 / IEC 60228 cl. 5 or 6 / BS 6360 cl. 5 or 6
core insulation special TPE
core colour code up to 0,34 mm² acc. DIN 47100 above 0,5 mm² black cores with continuous white numbering acc. to DIN VDE 0293, green-yellow earth core in the outer layer (3 cores and above)
stranding element cores stranded in layers with optimal lay-length
coat special separating foil
overall shield screening of tinned copper shield
outer sheath material special polyurethane

acc. to DIN VDE 0245, 0250, 0282
CE = The product is conformed with the EC Low-Voltage Directive 2014/35/EU.

inner conductor fine wire or extra fine wire conductors, bare copper acc. DIN VDE 0295 cl.5 or 6 / IEC 60228 cl. 5 or 6 / BS 6360 cl. 5 or 6
core insulation special TPE
core colour code up to 0,34 mm² acc. DIN 47100 above 0,5 mm² black cores with continuous white numbering acc. to DIN VDE 0293, green-yellow earth core in the outer layer (3 cores and above)
stranding element cores stranded in layers with optimal lay-length
coat special separating foil
overall shield screening of tinned copper shield
outer sheath material special polyurethane
rated voltage up to 0,34 mm² 350V above 0,5 mm² U0/U 300/500 V
test voltage up tp 0,34 mm² - 1,5 kV, 5 minutes above 0,5 mm² - 3,0 kV, 5 minutes
inductance 0,69 mH/km
bending radius moved 7,5
operation temp. fixed -40°C … +80°C
operation temp. moved -30°C … +80°C
fire behavior flame retardant
fire test acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1

Contact

Export

Management

Angela Mesarosch

Management Eastern Europe

phone +43 7228 20088-133
Fax +43 7228 20088-200
Mobil +43 664 9624355
mesarosch.angela@acs.at

Prok. Manfred Lederhilger

Export Management

phone +43 7228 20088-342
Fax +43 7228 20088-349
Mobil +43 664 1724858
lederhilger.manfred@acs.at

Division Management

Veronika Jautz

Czech Republic and Slovakia

phone +43 7228 20088 132
Fax +43 7228 20088 200
jautz.veronika@acs.at

Jaroslav Loučka

Czech Republic and Slovakia

Mobil +42 0727 835 409
loucka.jaroslav@acs.at

Angela Mesarosch

Hungary, Romania, Slovenia, Croatia, Serbia, Macedonia

phone +43 7228 20088-133
Fax +43 7228 20088-200
Mobil +43 664 9624355
mesarosch.angela@acs.at

Export Sales Assistant

Bc. Mariana Horak

phone +43 7228 20088-131
Fax +43 7228 20088-200
horak.mariana@acs.at

Philipp Szatmari

phone +43 7228 20088 134
Fax +43 7228 20088 200
szatmari.philipp@acs.at