ACS Phone: +43 7228 20088 0
  • Video
    a cable length ahead!
    …always

SERVO-SKL-PP/C/ PUR/UL

Application

Supply cable optimised especially for the supply of DNC motors. These cables are specially designed for use in power drag chains, handling equipment, robotics, tooling machinery, processing and manufacturing machinery. The optimised outside diameter, reduced weight and excellent torsion characteristics facilitate use in multi-shift operation with extreme alternating bending stress cycles. Particularly recommended as a supply cable between frequency converters and servomotors.


art. no.
dimensions
colour
outer-Ø
weight
01132001 4 G 1,5 orange 10 175
01132002 4 G 2,5 orange 11,7 265
01132003 4 G 4 orange 12,8 390
01132004 4 G 6 orange 15 570
01132005 4 G 10 orange 18 800
01132006 4 G 16 orange 22 1450
01132007 4 G 25 orange 27,5 1650
01132008 4 G 35 orange 32 2400
01132009 4 G 50 orange 36,7 3150
01132010 4 G 70 orange 42,5 4600
01132011 4 G 95 orange 49,5 5800
inner conductor bare copper, ultra-fine wire acc. to DIN VDE 0295 Kl. 6 / IEC 60228 cl. 6
core insulation Polypropylen, halogen-free
core colour code black cores with continuous white numbering, green-yellow earth core in the outer layer
stranding element cores stranded in layers with optimal lay-length and stabilising filler
coat fleece wrapping facilitates sliding
overall shield braid shield copper tinned
outer sheath material PUR

acc. to VDE, UL AWM Style 21223, CSA AWM
CE = The product is conformed with the EC Low-Voltage Directive 2014/35/EU.

inner conductor bare copper, ultra-fine wire acc. to DIN VDE 0295 Kl. 6 / IEC 60228 cl. 6
core insulation Polypropylen, halogen-free
core colour code black cores with continuous white numbering, green-yellow earth core in the outer layer
stranding element cores stranded in layers with optimal lay-length and stabilising filler
coat fleece wrapping facilitates sliding
overall shield braid shield copper tinned
outer sheath material PUR
rated voltage acc. to UL/CSA = 1000 V acc. to VDE Uo/U = 600/1000 V
test voltage 4000 V
insulation resistance min. 20 MOhm x km
bending radius moved 7,5
bending radius fixed 4
operation temp. fixed -40°C … +80°C
operation temp. moved -30°C … +80°C
fire behavior self-extinguishing and flame retardant
fire test acc. to VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)